Circuit diagram

©
Velleman page 19
LAB1 Technical Doc
Low voltage Dielectric strenght
MR-079-2005
EUT: LAB 1 (Prototype)
Manufacturer: Velleman ( Witness S.Santens)
Operating Condition: Normal
Test Site: ESM EMC centre
Operator: Meuleman Hendrik
Test Specification: IEC60065 (1998)
Comment: Pré-compliance Power supply connected with Multimeter
Date of Test: 1/06/2005
Short Description: Dielectric strength test 1 minute
Test result:
3KV between mains (L+N) connection and soldering iron: PASS
3KV between mains (L+N) connection and supply GND: PASS