Circuit diagram
©
Velleman page 12
LAB1 Technical Doc
Radiated disturbance Field
MR-079-2005
EUT: LAB1 (Prototype)
Manufacturer: Velleman ( Witness S.Santens)
Operating Condition: Normal
Test Site: ESM EMC centre
Operator: Meuleman Hendrik
Test Specification: CISPR22 / EN55022 Class B
Comment: Pré-compliance Power supply connected with Multimeter
Start of Test: 1/06/2005 / 9:31:01
SCAN TABLE: "CISPR22 Field"
Short Description: CISPR22 Field Strength
Start Stop Step Detector Meas. IF Transducer
Frequency Width Time Bandw.
30.0 MHz 1.0 GHz 80.0 kHz QuasiPeak 10.0 ms 120 kHz CBL61113M