User manual

HAM263D
00 (10/10/2008) VELLEMAN
14
General status LEDs
EXIT/ARMED ON System armed (whole system or one of the partitions)
OFF System disarmed (the whole system)
Flash System in exit delay period
AC POWER ON AC power normal
Flash AC power failure
Flash Alternatively
with Battery LED
System in Standby mode
BATTERY ON Battery low
OFF Battery normal
Flash Battery under testing
Flash Alternatively
with AC power
LED
System in Standby mode
PROGRAM ON System in programming mode
OFF System in normal operation mode
PART. 1 ON Partition 1 armed
OFF Partition 1 disarmed
Flash During Exit Delay
PART. 2 ON Partition 2 armed
OFF Partition 2 disarmed
Flash During Exit Delay
FORCED TO ARM ON System will be forced to arm if the faulty zone is not
cleared
OFF System armed normally
Flash System forced to arm with the faulty zone(s) bypassed
by the system
Zone status LEDs
ON Zone abnormal
OFF Zone normal
Fast flashing Zone was or still is in alarm mode
Fast flashing, 3x with
stopping interval
Zone was in alarm mode and is stored in alarm memory. System
is disarmed
Slow flashing Zone is bypassed
Control key buttons description
There are 14 buttons for code entry and function confirmation
0 ~ 9 Numeric buttons for code entry
* # For function confirmation
HOME For home mode arming and programming
BYPASS For (temporarily) bypassing zones while arming system