MFRC522
Standard performance MIFARE and NTAG frontend
The ComIrqReg register’s ErrIRq bit indicates an error detected by the contactless UART
during send or receive. This is indicated when any bit is set to logic 1 in register ErrorReg.
8.5 Timer unit
The MFRC522A has a timer unit which the external host can use to manage timing tasks.
The timer unit can be used in one of the following timer/counter configurations:
Timeout counter
Watchdog counter
Stop watch
Programmable one shot
Periodical trigger
The timer unit can be used to measure the time interval between two events or to indicate
that a specific event occurred after a specific time. The timer can be triggered by events
explained in the paragraphs below. The timer does not influence any internal events, for
example, a time-out during data reception does not automatically influence the reception
process. Furthermore, several timer-related bits can be used to generate an interrupt.
The timer has an input clock of 13.56 MHz derived from the 27.12 MHz quartz crystal
oscillator. The timer consists of two stages: prescaler and counter.
The prescaler (TPrescaler) is a 12-bit counter. The reload values (TReloadVal_Hi[7:0] and
TReloadVal_Lo[7:0]) for TPrescaler can be set between 0 and 4095 in the TModeReg
register’s TPrescaler_Hi[3:0] bits and TPrescalerReg register’s TPrescaler_Lo[7:0] bits.
The reload value for the counter is defined by 16 bits between 0 and 65535 in the
TReloadReg register.
The current value of the timer is indicated in the TCounterValReg register.
When the counter reaches 0, an interrupt is automatically generated, indicated by the
ComIrqReg register’s TimerIRq bit setting. If enabled, this event can be indicated on
pin IRQ. The TimerIRq bit can be set and reset by the host. Depending on the
configuration, the timer will stop at 0 or restart with the value set in the TReloadReg
register.
The timer status is indicated by the Status1Reg registers TRunning bit.
Table 18. Interrupt sources
Interrupt flag Interrupt source Trigger action
IRq timer unit the timer counts from 1 to 0
TxIRq transmitter a transmitted data stream ends
CRCIRq CRC coprocessor all data from the FIFO buffer has been processed
RxIRq receiver a received data stream ends
IdleIRq ComIrqReg register command execution finishes
HiAlertIRq FIFO buffer the FIFO buffer is almost full
LoAlertIRq FIFO buffer the FIFO buffer is almost empty
ErrIRq contactless UART an error is detected