Operating Instructions Electronics module VEGASON series 60 Ultrasonic
Contents Contents 1 About this document 1.1 1.2 1.3 2 6.3 . . . . . . . . . . . . . . . . . . . . General instructions. . . . . . . . . . . . . . . . . . . Mounting preparations VEGASON 61, 62, 63 Mounting preparations VEGASON 64, 65, 66 Mounting procedure, two-wire instruments. . . Mounting procedure, four-wire instruments . . .. 7 .. 8 .. 8 .. 9 . . 11 Preparing the connection . . . . . . . . . . . . . . . . . 13 Connection procedure . . . . . . . . . . . . . . . . . . .
About this document 1 About this document 1.1 Function This operating instructions manual has all the information you need for quick mounting and setup of a replacement module. Please read this manual before you start setup. 1.2 Target group This operating instructions manual is directed to trained, qualified personnel. The contents of this manual should be made available to these personnel and put into practice by them. 1.
For your safety 2 For your safety 2.1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the operator. During work on and with the device the required personal protection equipment must always be worn. 2.2 Appropriate use Oscillator, emitting electronics, housing or process components are replacement components for existing sensors. 2.
Product description 3 Product description 3.1 Configuration Scope of delivery The scope of delivery encompasses: l l Electronics module VEGASON series 60 Documentation - this operating instructions manual 3.2 Principle of operation Area of application The VEGASON series 60 electronics module is suitable for exchange with VEGASON series 60 ultrasonic sensors. It is available in different versions (see chapter "Mounting preparations"). 3.
Product description l l Storage and transport temperature l l Protected against solar radiation Avoiding mechanical shock and vibration Storage and transport temperature see "Supplement Technical data - Ambient conditions" Relative humidity 20 … 85 % 30206-EN-070510 6 Electronics module - VEGASON series 60
Mounting 4 Mounting 4.1 General instructions If the electronics module is defective, it can be replaced by the user. In Ex applications only one instrument and one oscillator with respective Ex approval may be used. If there is no electronics module available on site, one can be ordered from the VEGA agency serving you. Sensor serial number The new electronics module must be loaded with the order and factory data of the sensor.
Mounting 4.2 Mounting preparations VEGASON 61, 62, 63 4 … 20 mA/HART Oscillator SN-E.61H is suitable for VEGASON 61, 62, 63 4 … 20 mA/HART: l l l 4 … 20 mA/HART four-wire Electronics module SN-E.61V is suitable for VEGASON 61, 62, 63 - 4 … 20 mA/HART four-wire: l Profibus PA SN-E.61VX (X = without approvals) Oscillator SN-E.61P is suitable for VEGASON 61, 62, 63 Profibus PA: l l l Foundation Fieldbus SN-E.61HX (X = without approvals) SN-E.
Mounting l l Foundation Fieldbus SN-E.64VD (D = with approval CX, UX, UF according to VEGA product list) SN-E.64VG (G = with approval GX according to VEGA product list) Electronics module SN-E.64F suitable for VEGASON 64, 65, 66 - Foundation Fieldbus: l l l SN-E.64FX (X = without approvals) SN-E.64VD (D = with approval CX, UX, UF according to VEGA product list) SN-E.64VG (G = with approval GX according to VEGA product list) 4.
Mounting 3 Disconnect the connection cables according to the operating instructions manual of the respective sensor 4 Loosen the two holding screws with a screwdriver (Torx size T 10 or slot size 4) 1 2 Fig. 3: Loosen the screws 1 Electronics module 2 Screws (2 pcs.) 5 Pull the previous electronics out by holding the opening levers. Note: Make sure that the housing is not rotated during the electronics exchange. Otherwise the plug may be in a different position later.
Mounting 4.5 Mounting procedure, four-wire instruments Mounting steps The electronics module is located in the electronics compartment. The connection to the connection compartment is provided via internal connection cables. The illustration shows the position of the electronics compartment in the doublechamber housing. 1 Fig.
Mounting Note: Makr sure that the housing is not rotated during the electronics exchange. The connection plug in the housing for the electronics can then be in another position. 6 Insert the new oscillator carefully. Make sure that the plug is in the correct position.
Connecting to power supply 5 Connecting to power supply 5.1 Preparing the connection Warning: Before connecting to voltage supply, the plug connection between transducer and remote electronics must be provided in idle condition (see operating instructions manual of the respective sensor). Non-observance will damage the electronics! Only then, the sensor may be connected to voltage supply. 5.
Setup 6 Setup 6.1 Setup preparations With sensor serial number If you have ordered the electronics module by stating the sensor serial number, it is ready for the setup procedure after installation and connection to power supply. Without sensor serial number If you have ordered the electronics module without stating the sensor serial number or you are using a suitable electronics module from stock, you first have to load the sensor data after installation. Move via www.vega.
Setup Load this file with "Save target as" on your PC. Start PACTware™ and mode in the Service-DTM to the menu item "Electronics exchange". Transfer the XML file into the sensor. 6.2 Setup procedure, two-wire and four-wire electronics Adjustment As a rule, all settings already carried out on site with the previous electronics module such as min./max. adjustment, false echo fade-out etc., must be repeated.
Setup The Service-DTM confirms the successful input of the current values and indicates the actual current value. This value corresponds to the actual measured value taking the calibration into account. Adjustment As a rule, all settings already carried out on site with the previous electronics module such as min./max. adjustment, false echo fade-out etc., must be repeated. Tip: For this purpose, use the copy function of the indicating and adjustment module or the adjustment software PACTware™.
Maintain 7 Maintain 7.1 Instrument repair If a repair is necessary, please proceed as follows: You can download a return form (23 KB) from the Internet on our homepage www.vega.com under: "Downloads - Forms and certificates - Repair form". By doing this you help us carry out the repair quickly and without having to call for needed information.
Dismounting 8 Dismounting 8.1 Dismounting steps Take note of chapters "Mounting" and "Connecting to power supply" and carry out the listed steps in reverse order. 8.2 Disposal The replacement module consists of materials which can recycled by specialised recycling companies. We have purposely designed the electronic modules to be easily separable. WEEE directive 2002/96/EG This instrument is not subject to the WEEE directive 2002/96/ EG and the respective national laws (in Germany, e.g. ElektroG).
Supplement 9 Supplement 9.1 Technical data Technical data 30206-EN-070510 are stated in the operating instructions manual of the appropriate sensor.
VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info@de.vega.com www.vega.com ISO 9001 All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing.