Level and Pressure Operating Instruction Oscillators E14, E15, E17, E18 on capacitive electrodes with terminal insert
Exchange of electronics Replacement set Oscillator Capacitive electrodes With this adapter set it is possible to adapt the new oscillators E14, E15, E17 and E18 to capacitive electrodes with terminal insert. The replacement set must not be used for electrodes certified acc. to CENELEC, PTB Zone 0, WHG or VbF. On electrodes for adhesive products type 23.2… and 25.2… the replacement set is also not possible.
Exchange of electronics 1 7 2 brown white 6 5 4 3 1 2 3 4 5 6 7 Housing cover - new Oscilaltor E14, E15, E17, E18 Thread on hexagon Insturment housing Cover plate Adapter plate Changeover switch Capacitive electrodes EL 3
VEGA Grieshaber KG Am Hohenstein 113 D-77761 Schiltach Phone (0 78 36) 50 - 0 Fax (0 78 36) 50 - 201 e-mail vega@vega-g.de ISO 9001 Technical data subject to alterations 2.20 975 / Sept.