Supplementary instructions Connection cable IP 66/IP 68 (1 bar) Retrofit set/Accessory for plics sensors Document ID: 34107
1 Contents Contents 1 For your safety 1.1 1.2 1.3 1.4 .. .. .. .. 3 3 3 3 Mounting preparations . . . . . . . . . . . . . . . . . . . . . . . Mounting steps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 Appropriate use . . . . . . . . . . . . Impermissible use . . . . . . . . . . General safety instructions . . . . Safety instructions for Ex areas . 2 Product description 3 Mounting 3.1 3.2 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 For your safety 1 For your safety 1.1 Appropriate use The connection cable is used to retrofit existing plics sensors to achieve protection IP 66/IP 68 (1bar). 1.2 Impermissible use As a rule, the connection cable is not allowed to be used with four-wire instruments. Four-wire instruments are sensors whose power supply and measurement signal are transmitted over two separate pairs of wires. 1.
2 Product description 2 Product description Scope of delivery The scope of delivery encompasses: l l l Application area Connection cable with cable gland Blind stopper Documentation - this operating instructions manual The connection cable is suitable for the following plics sensors with aluminium or stainless steel housing: l l l l l l l l VEGAPULS series 60 VEGAFLEX series 60 and 80 VEGASON series 60 VEGACAL series 60 VEGABAR series 50 and 60 VEGACAP series 60 VEGASWING series 60 VEGAWAVE series 60
3 Mounting 3 Mounting 3.1 Mounting preparations Tools The following tools are required for mounting: l l l Blind stopper Spanner SW 24 for unscrewing the cable gland Spanner SW 9 for unscrewing the filter element Screwdriver size 4 for screwing in the blind stopper The blind stopper consists of adapter, O-ring and closing screw. It is assembled according to the following drawing: 1 2 3 Fig. 1: Assembly of blind stopper 1 2 3 Adapter O-ring Closing screw 3.
3 Mounting 5 6 5 6 2 1 5 3 6 5 6 4 Fig.
4 Connecting 4 Connecting 4.1 Connection procedure The electrical connection is carried out according to the operating instructions manual of the respective sensor. 4.2 Wiring plan VEGABAR series 50 and 60 4 1 2 3 3 Fig.
4 Connecting Wire colour Terminal, electronics module Black VEGACAP, VEGAVIB, VEGASWING series 60 Z-electronics 2 1 3 3 Fig. 5: Wire assignment, connection cable 1 2 3 Brown (+) and blue (-) to the sensor brown (+) and blue (-) to power supply or to the processing system Shielding Wire colour Terminal, electronics module Brown 1 Blue 2 Black VEGACAP, VEGAVIB, VEGASWING series 60 T-electronics 1 2 3 3 Fig.
4 Connecting Wire colour Terminal, electronics module 34107-EN-120524 Black Connection cable IP 66/IP 68 (1 bar) • Retrofit set/Accessory for plics sensors 9
5 Annex 5 Annex 5.1 Technical data Mechanical data Structure Standard lengths Min. bending radius at 25 °C/77 °F Diameter approx. Torque of the cable gland max. four wires, one steel cable, one breather capillary, screen braiding, metal foil, mantle 5 m (16.4 ft), 6 m (19.69 ft), 10 m (32.81 ft), 25 m (82.02 ft) 25 mm (0.985 in) 8 mm (0.
5 Annex ø 24 mm (15/16") SW24 ø 8 mm (5/16") 5.2 Dimensions 70 mm (2 3/4") 34107-EN-120524 Fig.
5 Annex 34107-EN-120524 12 Connection cable IP 66/IP 68 (1 bar) • Retrofit set/Accessory for plics sensors
34107-EN-120524 5 Annex Connection cable IP 66/IP 68 (1 bar) • Retrofit set/Accessory for plics sensors 13
5 Annex 34107-EN-120524 14 Connection cable IP 66/IP 68 (1 bar) • Retrofit set/Accessory for plics sensors
34107-EN-120524 5 Annex Connection cable IP 66/IP 68 (1 bar) • Retrofit set/Accessory for plics sensors 15
Printing date: VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com www.vega.com ISO 9001 All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing.