Manual
34 Capacitive electrodes EL …
Electrical connection
Separate housing
When there are ambient temperatures of more
than 80° C on the housing, a temperature
adapter must be used or the electronics must
be separated from the electrode and located at
a cool place. Hence the electronics can be
mounted in a separate housing at a distance of
up to 8 m from the electrode. Electrode and
housing are dispatched completely mounted.
Carry out the adjustment according to the
following figures. Only use VEGA-triax cable.
Choose the cable connection as short as
possible.
Capacitive rod and cable electrodes EL
Electrode EL 26 (EL 35) for adhesive
products
black
red
black
red
blue
(screen)