Operation Manual
76
VECTRON POS MINI II
9. Errors, possible reasons and
troubleshooting
This chapter informs you about possible reasons for errors that
occur when operating the Mini II and tells you how to remove them
yourself. Please contact your Vectron dealer if you cannot solve
the problem yourself.
Errors Possible reasons Troubleshooting
Mini II cannot be
switched on.
The safety plug is
not put into a live
socket.
Put the safety
plug of the sup-
plied power cord
into a grounded
socket with al-
ternating voltage
between 110 and
240 volt and which
is protected with a
fault current circuit
breaker.
The power cable
plug of the power
supply PS30 is not
put to the power
connector of Mini II.
Put the power cable
plug of the power
supply PS30 to the
power connector of
Mini II.
The On/Off key is
damaged.
Contact your
Vectron dealer.
The power supply
Vectron PS30 is
damaged.
Contact your
Vectron dealer.
The Mini II is dam-
aged.
Contact your
Vectron dealer.
The Mini II POS sys-
tem does not react
to your entries.
The signed-in oper-
ator is not author-
ized for the respec-
tive function.
Contact your