Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter V - page 22
STANDARD PROGRAMMING
EXAMPLE:
Configuration for an installation of 8 LEVELS including 2 BASEMENT.
If at Level
2
- Ground Level (Address
2A
), we desire «
RC
» displayed, we program
1C
to
parameter address
2A
(REPTxx : REPeaTer at level xx).
Level Address
15 37
14 36
13 35
12 34
11 33
10 32
931
830
72F
62E
52d
42C
32b
2 2A
129
028
Displayed on
digital indicator
Code to be
programmed
into the
controller
Displayed on
digital indicator
Code to be
programmed
into the
controller
Displayed on
digital indicator
Code to be
programmed
into the
controller
000 130d ES1A
101 140E RJ1b
202 150F
RC 1C
303 1610 RH1d
404 1711 RB1E
505 1812 SS1F
606 1913 P020
707 -014 P121
808 -115 P222
909 -216 P323
10 0A -3 17 RS 24
11 0b -4 18 ME 25
12 0C -5 19
n
Select address
2A
corresponding to the
2
nd level with
Push buttons.
RAM
PAR
ADR/DON
MODIF
1
o
1 second later, a value is displayed, if this value suits you
(our example
1C
) Don’t change it, if not, slide the
ADR/DON
-
MODIF
switch to
MODIF
ADR/DON
MODIF
2
p
Modify the value to obtain
1C
with push buttons to
increase/decrease to the new value.
Register the new value by pushing and releasing both
buttons
at the same time
.
RAM
PAR
ADR/DON
MODIF
3
q
Slide the
ADR/DON - MODIF
switch to
ADR/DON
The new value is memorised.
ADR/DON
MODIF
4