Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter III - page 3
MOTOR SCREENING CABLE
RECAV1
RE positioning in
speed V1?
Add. 08
Seg. 7 ON
☺
ADR/DON
MODIF
ECRIT
BG17
PAR
RAM
Y
CONNECTION
L1
L2
L3
Motor
terminal
earth
11
12
13
L
S
W2
U2
V2
U1
V1
W1
Star connection
Motor 220 V / 380 V Mains 380 V
CONTROLLER:
Phase
Screened cable
cables
Yellow/Green
earthing cable
TO INSERT THE SCREENING CABLE
LOWER THE MOBILE PLATE
USING A SCREWDRIVER
Screening cable
11 12 13PE
Note: Keep the motor cable as far apart from the power cable as
possible, inside as well as outside the controller.
MOTOR:
W2 U2
V2
U1
V1
W1
Screening flat cable
linked in the shortest way
to the earth terminal
Phase cables
Screened cable
earthing cable
Yellow/Green
Terminal box
Motor earth
terminal
Note: The cables should only be separated from the screening
once inside the terminal box.