Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter II - page 2
CONNECTING THE SAFETY LANE
WITH AUTOMATIC DOORS AND MACHINE ROOM INSPECTION BOX
GOVERNOR
PULLEY
(§ 9.9.11.3)
RETURN
SWITCH
Vn > 2.5 m/s. (§ 9.6.1.b)
IN THE COMPENSATION ROPES
CONTACT OF THE TENSION
PIT BOTTOM
SWITCH
(§ 5.7.3.4)
SHAFT EMERGENCY
EXIT
(§ 5.2.2.2.2)
(§ 8.11.5.2)
+ SECURITY I.G.H.
(Art. GH33)
EMERGENCY DOOR
CAR STOP BUTTON
(§ 14.2.2.2)
CAR SAFETY
TRAP SWITCH
(§ 8.12.5.2)
EMERGENCY
(§ 8.15.b)
CAR ROOF
STOP ON
BOTTOM OVER
TRAVEL LIMIT
(§ 10.5.3.1.b.2)
(§ 10.5.3.1.b.2)
TOP OVER
TRAVEL LIMIT
TRANSMISSION OF THE
CAR POSITION TO THE
(§ 10.5.2.3.b)
FINAL LIMIT SWITCH
OVERSPEED
GOVERNOR
(§ 9.9.11.1)
TRIPPING
(§ 9.9.11.2)
OVERSPEED
GOVERNOR
RELEASE
BUFFER
(§ 10.4.3.4)
DISSIPATION
PULLEY ROOM
STOP
(§ 6.4.5)
POWER SUPPLY
SAFETY LANE
(§ 14.1.1.3)
PROTECTION
CONTACT
(§ 8.9.2), (§ 7.7.6.2)
(§ 7.7.4)
CAR GATE
LOCKS
(§ 5.4.3.2.2)
(§ 7.7.3.1)
LANDING
(§ 9.8.8)
SAFETY
GEAR SWITCH
INSPECTION
P 82.211 (§ 5.7.2.2.b)
DECRET 95-826 (§ I.1.1)
FINAL LIMIT SWITCH
GV/PV DE
MO
Maxi
250V
Visa
Normalisation
Date
Responsable
10 / 07 / 97
H. MARY
MO DE
10
( K12 )
L
S
COM1
( K14 )
S
L
R 63
R 62
R 68 R 67
MAN/
GM GD
INSPECTION NORMAL
INS
MO DEPVGV
( K28 )
( K29 )
( K30 )
RS RS
LS
LS
1S 1BRSCV 2A FRV121C 44C3FRV2 8A 1086
OPTION
DISCONNECTION
SWITCH
SAFETY LANE
ELECTRO-MECHANICAL RAIL
BG15
MAIN BOARD
VEC01
VECTOR FREQUENCY DRIVE
MACHINE ROOM
(§ 14.2.1.4)
INSPECTION
BOX
STOP IN
INSPECTION BOX
INSPECTION BOX
(§ 14.2.1.3)
ISOLATING
TERMINAL
BLOCKS
Used
Not used
GDGM
5
If you haven't
the Terminal
a Doors
schunt
Security Bridge
Board,
5 & 6
MACHINE ROOM
INSPECTION BOX
SHUNT 2A & 3
IN ABSENCE OF
FU4 - BG22