Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter I - page 36
B) In segment mode
Go to the parameter address as previously explained (e.g. 08).
If the contents are displayed as a figure (82 in the example below), check that the right hand
switch is in the upper position, and press both buttons at the same time; this will pass you into
segment mode. The current address will be displayed followed by the contents shown in
segments. If not pass onto stage
.
RAM
PAR
ADR/DON
MODIF
ECRIT
BG17
1'
1
RAM
PAR
ADR/DON
MODIF
BG17
Press
and release ...
RAM
PAR
ADR/DON
MODIF
ECRIT
BG17
ADR/DON
MODIF
RAM
PAR
ECRIT
BG17
}
}
TOP
ROW
BOTTOM
ROW
The left-hand button acts on the TOP ROW of
segments (4 to 7),
The right-hand button acts on the BOTTOM
ROW
of segments (0 to 3).
Slide the ADR/DON-MODIF switch to MODIF.
In our example we want to activate the "flashing direction arrow"
function (address 08 segment 5).
We have to light up segment 5 while keeping on all other segments in
their present state
ADR/DON
MODIF
2
RAM
PAR
ADR/DON
MODIF
ECRIT
BG17
Seg 5
flashing direction arrow
2
Press
once
...
RAM
PAR
ADR/DON
MODIF
ECRIT
BG17
2
Seg 5
flashing direction arrow
Press
once
...
RAM
PAR
ADR/DON
MODIF
ECRIT
BG17
Seg 5
flashing direction arrow
Repeat stages
and
shown on the previous
page.