ISPLAY MODES
Depending on the information to be displayed, the MB32 VECTOR uses the most
appropriate method of showing the information.
Digit Mode
The
digit mode
is useful to read or programme times, or the number of floors, or the number
of doors for example.
Example: If we have 2 door operators, we program 02 at address 03.
Segment Mode
The segment mode uses the individual vertical segments on the display as shown below.
This mode is useful to activate or deactivate different functions:
Example: To activate the "flashing direction arrows" option, segment 5 at
address 08 must be ON.
The segment mode is also useful to view the state of inputs and outputs:
Example: To check that the
C0
input (car call to level 0) is correctly read by
the MB32 VECTOR, you need to look at segment 0 at address
00.
To change from digit to segment mode and vice-versa, slide the ADR-DON-MODIF switch
to ADR/DON and press both buttons at the same time, and release.
Segment 6 Segment 5
Segment 7 Segment 4
Segment 3 Segment 0
Se
g
ment 2 Se
g
ment 1