Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter I - page 29
T
RANSFER OF THE SETTINGS INCLUDED IN THE DIAGNOSTIC TOOL TOWARD THE
VVVF.
T
O REMIND YOURSELF OF THE ADDRESS
T
O CHANGE THE PARAMETERS IN DECIMAL MODE
!
WARNING: this operation overwrite on the parameters included in the VVVF door drive
!
Press the 2 end buttons,
you read,
« READ PARAMETERS »
Display
« WRITE PARAMETERS »
using button 1
Validate by pressing the
« VALID » button
..... Transfert
Press the 2 end buttons to
return to normal mode
READ PARAMETERS
MODIF. CLEAR VALID.
1000 100 10 1
WRITE PARAMETERS
MODIF. CLEAR VALID.
1000 100 10 1
x 1
WRITE Ad.
MODIF. CLEAR VALID.
1000 100 10 1
F8xx
MODIF. CLEAR VALID.
1000 100 10 1
000 V0 0,150m/s
Note: You can transmit the VVVF parameters in the E²ROM of the box at addresses 00, 40, 80 or C0 in the box
VEC03. For that, press the 2 end buttons, than on the button 1 to pass on « WRITE » mode than press the 2
« MODIF » buttons and than modify the right number at 00, 40, 80 or C0 with the 10 button than press
« VALID » to validate.
READ PARAMETERS
MODIF. CLEAR VALID.
1000 100 10 1
WRITE PARAMETER
MODIF. CLEAR VALID.
1000 100 10 1
40 Octets - > 00
MODIF. CLEAR VALID.
1000 100 10 1
MODIF. CLEAR VALID.
1000 100 10 1
x 8
40 Octets - > 00
40
80
C0
Ex: Copy the Parameters
memorised at address 80
in the box to the VVVF
MODIF. CLEAR VALID.
1000 100 10 1
READ Add. F8xx
If you forget the address you are changing, or the previous value
shown, just press both
MODIF
buttons.
004 V2 2,00m/s
MODIF. CLEAR VALID.
1000 100 10 1
After selecting the required language (see previous page) you can access the parameters and
change them if required.
Reset the display by pressing
both CLEAR buttons
at the same time
To change the V2 speed for
example, display address 004
by pressing button 1
Press both
MODIF buttons
at the same time
000 V0 0,150m/s
MODIF. CLEAR VALID.
1000 100 10 1
004 V2 2,00m/s
4 x
MODIF. CLEAR VALID.
1000 100 10 1
MDF V2 2,00m/s
MODIF. CLEAR VALID.
1000 100 10 1
Press button 10 5 times to obtain
the desired speed
Register the new speed by
pressing both VALID buttons at
the same time
MDF V2 2,50m/s
5 x
MODIF. CLEAR VALID.
1000 100 10 1
004 V2 2,50m/s
MODIF. CLEAR VALID.