Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter I - page 26
FREQUENCY DRIVE PARAMETER / DIAGNOSTIC
COMMUNICATION DEVICE
This chapter contains information which will allow you to adapt the VECTOR
equipment to the specific conditions of the lift on which it is installed.
This adaptation is controlled by parameters, which you can modify according to your needs
using the removable parameter / diagnostic communication device as described below in the
paragraph Accessing the parameters.
The parameters are memorised in a particular type of chip called an EEPROM
1
(or
E2PROM) which
keeps the information even when the equipment is switched off
.
Each parameter is linked to an abridged name and an address which corresponds to
the position at which it is memorised in the EEPROM chip.
Accessing the parameters
As mentioned above, you can see and modify the parameters using the
parameter/diagnostic communication tool; this consists of a 16 characters LCD display with
four push buttons, which is connected to the VEC01 board by a standard Male/Female Sub-
D 9 pt cable.
1 EEPROM stands for Electrically Erasable Programable Read Only Memory.
AUTINOR
TO MODIFY THE VALUES
THOUSANDS
HUNDREDS TENS
UNITS
RESET TO ZERO
TO VALIDATE THE DATA
VEC01
Standard Male/Female
Sub-D9 pt cable
MODIF. CLEAR VALID.
1000 100 10 1