FAULT N° DESIGNATION
-56-
« ISO » RELEVELLING CONTACTOR NOT ENERGISED WHEN
REQUIRED.
( B )
-57-
LIFT HAS GONE PAST RELEVELLING ZONE DURING RELEVELLING
MOVEMENT.
( A )
-58-
MORE THAN 6 RELEVELLING MOVEMENTS.
( B )
-59-
RELEVELLING MOVEMENT EXCEEDS RELEVELLING TIME.
( A )
-60-
MAXIMUM PROGRAMMED HEIGHT IS TOO HIGH.
( A )
-61-
ERROR IN THE FLOOR PROGRAMMING.
( A )
-62-
FAULT WITH THE O03 TAPE HEAD.
( A )
-63-
CAR IS AT THE TOP AND THE BOTTOM AT THE SAME TIME, OR
O03 TAPE HEAD NOT POWERED.
( A )
-64-
CAR INSPECTION AND MACHINE ROOM INSPECTION SWITCHED
ON AT THE SAME TIME.
( B )
-65-
PERMANENT FAULT ON THE VF. CHECK THE FAULT CODE ON
THE MLIFT.
-66-
TEMPORARY FAULT CODE ON THE VF. CHECK THE FAULT CODE
ON THE MLIFT.
-69-
MOVEMENTS AFTER SAFETY LANE LIMITS HAVE BEEN CUT.
( A )
-70-
ANTI-CREEP NOT DROPPED WHEN REQUIRED.
( A )
-71-
ANTI-CREEP DROPPED WHILE CAR IN MOTION.
( B )
-72-
ANTI-CREEP NOT DROPPED WHEN CAR AT REST.
( A )
-73-
OIL LEVEL FAULT.
( A )
-74-
MINIMUM OIL LEVEL.
( A )
-75-
STAR CONTACTOR NOT ENERGISED WHEN REQUIRED.
( C )
-76-
DELTA CONTACTOR NOT ENERGISED WHEN REQUIRED.
( C )
-77-
LIGNE CONTACTOR NOT ENERGISED WHEN REQUIRED.
( C )
-78-
STAR OR DELTA CONTACTOR NOT DROPPED.
( C )
-79-
OIL TEMPERATURE TOO HIGH.
( C )