FAULT CODES LIST (1/3)
Faults displayed by the 32 series. (BG15 board)
The letter shown in brackets signifies the type of fault.
• ( A )
Signifies that the fault is permanent and that the power supply needs to be
turned off and back on again to RESET.
• ( B )
Signifies that the fault is temporary and that if the cause of the fault
disappears, the controller will work again as normal.
• ( C )
Signifies that the fault is temporary, asked for by the technician when
programming "provisional fault". (DCOPRO - Ad.07 - Bât.06)
• ( D )
Signifies that the fault can be ignored if the technician so requires.
• ( * )
Signifies that the fault is not registered in the fault list. The fault list on the
Series 32 can be found at addresses 00, 01, 7E, 7F (left hand switch in
lower position). Address 00 shows the last fault and address 7F the oldest
fault.
BEFORE LEAVING THE SITE, SET THE FAULT LIST BACK TO 00. IN
THIS WAY YOU CAN KEEP BETTER TRACK OF ANY BREAKDOWNS.
WARNING :
PLEASE TAKE PRECAUTIONS WHEN YOU SEND US YOUR ELECTRONIC BOARDS
(USE ANTI-STATIC BAGS)
FAULT N° DESIGNATION
-01-
0V CONNECTED TO EARTH.
( B )
-02-
SLOW SPEED TIME EXCEEDED.
( A )
-03-
INSPECTION TIME EXCEEDED.
( D )
-04-
SAFETY LANE CUT BEFORE « 6 ».
( B )
-05-
FAN THERMISTOR (THV).
( B )
-06-
CONTINUAL ABSENCE OF « 10 » WHEN RETURNING TO GROUND.
( A )
-07-
ERROR IN THE PROGRAMMING OF THE SPG1 TO SPG4 OUTPUTS.
( A )
-08-
DEPARTURE DELAY (SUSD).
( B,*)
-09-
MOTOR THERMISTOR (STH).
( B )
-10-
INVERSION IN THE ROTATION DIRECTION (DETECTED BY THE
TAPE HEAD)
( A )
-11-
INCORRECT READING BY THE TAPE HEAD OR PROBLEM WITH
FUSES FU3 AND FU4.
( A )
-12-
ONE OF THE CONTACTORS NOT DROPPED ON ARRIVAL.
( C )
-13-
FAST SPEED CONTACTOR NOT DROPPED IN SLOW SPEED
( C )
-14-
SLOW SPEED CONTACTOR NOT ENERGISED WHEN REQUIRED
( C )
-15-
MO OR DE CONTACTOR NOT ENERGISED WHEN REQUIRED OR
FU9 OUT OF SERVICE (24R).
( C )
-16-
UP END LIMIT ON TEST (FREV).
( B,*)