Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 96
CONTROLLER PARAMETERS TABLE (2/3)
Add Seg. 7 Seg. 6 Seg. 5 Seg. 4 Seg. 3 Seg. 2 Seg. 1 Seg. 0
48
RCAME1
N00
PORCAB1
N00
OUAVAP1
N00
STP1OU
N00
SER1I
N00
OUNSIM1
N00
49 to 56
RCAME1
Nxx
PORCAB1
Nxx
OUAVAP1
Nxx
STP1OU
Nxx
SER1I
Nxx
OUNSIM1
Nxx
57
RCAME1
N15
PORCAB1
N15
OUAVAP1
N15
STP1OU
N15
SER1I
N15
OUNSIM1
N15
58
TDEMYD - STAR/DELTA (Y/D ) START TIME (0 TO 6 SECONDS [IN
1
/
10
SEC])
59
TARMVT - MOVEMENT STOP TIME (0 TO 2,55 S. [IN
1
/
100
SEC])
5A
TPMPVM - SLOW SPEED MOVEMENT PROLONGATION TIME (0 TO 0,5 SEC. [IN
1
/
100
SEC])
5B
TYPHYD - TYPE OF HYDRAULIC POWER UNIT
5C
RAMDES BASE8N DNH DEMDIR TAQUET
5D
DPLX NIVSIN DSERVS
5E
TRAUN0 - AUTOMATIC HOMING TIME TO LEVEL 0 (0 TO 15 MINUTS. [IN MINUT])
5F
STPREG DCTQET REGDRAL
60
VERSTF2 P2SFCOU P2SFCFE PMAFCP2 MSTPMP2 AMPSEC2 MSTPRP2
61
TP02 - REAR DOOR TIME (2 TO 255 SECONDS [IN SECONDS])
62
TREP2 - REAR DOOR RE-OPEN TIME (1 TO 255 SECONDS [IN SECONDS])
63
CABVID SHTCS/ ISOCLI RMLIFT REGUL
OuAvARCli
TPRAL
64
TIRP2 - REAR DOOR RELAY INVERSION TIME (0 A 2,55 S. [IN
1
/
100
SEC])
67
TIGPO2 - REAR DOOR INTEGRATOR TIME (1 TO 255 SECONDS [IN SECONDS])
68
RCAME2
N00
PORCAB2
N00
OUAVAP2
N00
STP2OU
N00
SER2I
N00
OUNSIM2
N00
69 to 76
RCAME2
Nxx
PORCAB2
Nxx
OUAVAP2
Nxx
STP2OU
Nxx
SER2I
Nxx
OUNSIM2
Nxx
77
RCAME2
N15
PORCAB2
N15
OUAVAP2
N15
STP2OU
N15
SER2I
N15
OUNSIM2
N15
SPG4 SPG3 SPG2 SPG1 SPG4 SPG3 SPG2 SPG1
78
RF - OVERLOAD BUZZER VSU - OVERLOAD INDICATOR
79
VHS - OUT OF SERVICE INDICATOR GONG - GONG OUTPUT
7A
INH1 - DOOR CELL OVER-RIDE OUTPUT VPMP - FIRE SERVICE INDICATOR
7B
LU - AUTOMATIC CAR LIGHT
7E
DEF N-2 - FAULT CODE 3
7F
DEF N-3 - FAULT CODE 4
SLOW DOWN DISTANCE AS A FUNCTION OF THE OIL TEMPERATURE
C0
TEMPERATURE AT WHICH THE DISTANCE C8 IS CHOSEN
C1
TEMPERATURE AT WHICH THE DISTANCE C9 IS CHOSEN
C2
TEMPERATURE AT WHICH THE DISTANCE CA IS CHOSEN
C3
TEMPERATURE AT WHICH THE DISTANCE CB IS CHOSEN
C4
TEMPERATURE AT WHICH THE DISTANCE CC IS CHOSEN
C5
TEMPERATURE AT WHICH THE DISTANCE CD IS CHOSEN
C6
TEMPERATURE AT WHICH THE DISTANCE CE IS CHOSEN
C7
TEMPERATURE AT WHICH THE DISTANCE CF IS CHOSEN
SLOW DOWN DISTANCE AS A FUNCTION OF THE OIL TEMPERATURE
C8
à SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C0
C9
à SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C1
CA
à SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C2
CB
à SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C3
CC
à SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C4
CD
à SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C5
CE
à SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C6
CF
à SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C7
SLOW DOWN DISTANCE AS A FUNCTION OF THE OIL TEMPERATURE
A8
Ä SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C0
A9
Ä SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C1
AA
Ä SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C2
AB
Ä SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C3
AC
Ä SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C4
AD
Ä SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C5
AE
Ä SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C6
AF
Ä SLOW DOWN DISTANCE (EN %) CHOSEN UNTIL TEMPERATURE C7
MINIBLOC
FF
CA CB INS POMP NIV 10 8 6