Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter I - page 23
LOCATION AND FUNCTION OF FUSES
SPARE FUSE
ONLY USE PROTISTORS CAPABLE OF WHITHSTANDING 600V
THE USE OF OTHER FUSES IS DANGEROUS AND COULD DAMAGE
THE TRANSISTORS IF THERE IS A POWER SURGE OR SHORT CIRCUIT.
ATTENTION !!!
AND SPECIALLY CONCEIVED TO PROTECT SEMI-CONDUCTORS.
N°2
N°3
N°4
N°5
N°6 / N°7
MODEL PROTISTOR
25 A (10x38)
40 A (14x51)
50 A (14x51)
63 A (22x58)
80 A (22x58)
OPERATOR 1
L1PA-L2PA-L3PA
2A-380V dim: 8,5 x 31,5
PROTECTION
OF THE INPUT PHASES
FOR THE DOOR MOTOR
DOOR 1 AND DOOR 2
RECTIFIED
CURRENT
PRESENT
(brake, retiring ramp,
electrovalves, anti-creep ...)
YELLOW LED
FU1
5A-250V dim: 5 x 20 TIME LAG
ELECTRONIC
AND SIGNAL
POWER SUPPLY
PROTECTION
FU2
2,5A-250V dim: 5 x 20 QUICK ACTIN
G
COMB, PROTECTION WIRE
FOR CALL PANEL BUTTONS
5A-250V dim: 5x20 TIME LAG
for FU2 & FU3 if
Type 1 transformer
for FU1 & FU7.
FU1
5A-250V dim: 5 x 20 TIME LAG
PROTECTION
BOX
BH07
FU7
5A-250V dim: 5 x 20 TIME LAG
PROTECTION
CURRENT
RECTIFIED
TYPE A
for FU1
5A-250V dim: 5x20 TIME LAG
SPARE FUSE
BG15
BG22
VEC01
DC CURRENT
PROTECTION
(brake, retiring ramp,
electrovalves ...)
T1=5A / T2= 2A
250V dim: 5 X 20
FU2, FU3
TIME LAG
transformer
For type 1 or 2
FU4
SAFETY LANE
POWER SUPPLY
PROTECTION
2A-250 V dim: 5 X 20 TIME LAG
5A-250 V dim: 5 X 20 TIME LAG
FU1
POWER SUPPLY
EQUIPMENT
PROTECTION
(MAIN BOARD)
ELECTRONIC
CURRENT PRESENT
RECTIFIED
RED LED
2A-250V dim: 5x20 TIME LAG
for FU2 & FU3 if
Type 2 transformer
for FU4.
SPARE FUSE
PROTECTION
SAFETY LANE
for FU2 and FU5
2,5A-250V dim: 5x20
SPARE FUSE
QUICK ACTING
FuVe
PROTECTION
FAN
COOLING
TRANSISTOR
0,5A-250 V dim: 5 X 20 QUICK ACTING
FU1 (2A)
SIGNAL POWER SUPPLY
PROTECTION
ELECTRONIQUE AND
2A-250 V dim: 5 X 20 TIME LAG
VEC12
If you should replace the motor current
It is IMPERATIVE to followed
the same path wire
measuring device VEC12
MEASURING DEVICE
MOTOR CURRENT
POWER CONTACTORS
BRAKE CONTACTOR
The position of FU+ is depending
of the V.F. Model
FU+
DC PROTECTION BY PROTISTOR
DRIVE MODEL.
(SEE TABLE BELOW)
DEPENDING ON THE
3 PHASE NETWORK
CURRENT FILTER
E2ROM
(PARAMETERS)
E2ROM
(FAULTS)
NOTCH
MICROPROCESSOR
PROGRAMME
for FU1
2A-250V dim: 5x20 TIME LAG
SPARE FUSE
GE 32
TB 191
6A 4A
L1P
6A 4A
L2P
2A 2A
L3P
LA 32 -
380 V dim: 6 X 32
R
R
R
!
FU5
2,5A-250V dim: 5 x 20 QUICK ACTIN
G
24RB, PROTECTION WIRE
FOR CALL PANEL BUTTONS