Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 87
OUTPUTS DEFINITIONS
In order to make the outputs visible, we must put the little switch on the left up in the
" RAM " position.
NOTE CONCERNING THE OUTPUTS:
Certain Outputs are ELECTRONIC and can only give out 50 mA under 24V (1.2W
max). We will indicate this by putting (S ELEC) with their definition.
Certain Outputs are DRY relay CONTACTS whose common connection is
accessible. We will indicate this by putting (S CONT) with their definition.
Certain Outputs are DRY relay CONTACTS whose common connection is not
accessible because it is already linked internally to the 24R potential. We will indicate this
by putting (S CONT 24R) with their definition.
It is suitable therefore to interface the outputs in accordance with the component to
command.
• Ram Address
13
:
best displayed in segment mode.
Segment
7
:
CREP
(Common Position Repeater) (S ELEC).
This shows us the state of the Common Position Repeater (CREP).
If segment 7 blinks, the CREP is " ALIVE".
If segment 7 is off or remains on, the CREP is "DEAD".
Segment
6
:
LU
(Automatic Car Light) (S ELEC).
This shows us the state of the Automatic Car Light (LU).
Segment 6 is on when the LU output is activated and gives out 0 Volt.
Segment 6 is off when the LU output is de-activated and gives out 24 Volts.
Segment
5
:
FE1
(Front Door Close Signal Output) (S CONT).
This shows us the state of the Front Door Close Signal Output (FE1).
Segment 5 is on if the Front Door Close Signal Output is fed.
Segment 5 is off in the reverse case.
Segment
4
:
OU1
(Front Door Open Signal Output) (S CONT).
This shows us the state of the Front Door Open Signal Output (OU1).
Segment 4 is on if the Front Door Open Signal Output is fed.
Segment 4 is off in the reverse case.
Segment
3
:
CAM
(Retiring Ramp).
This shows us the state of the Retiring Ramp output (CAM).
Segment 3 is on if the Retiring Ramp output is activated.
Segment 3 is off in the reverse case.