INPUTS DEFINITIONS
Ram Address
62
:
best displayed in segment mode.
Segment
7
: Not used.
Segment
6
: Not used.
Segment
5
: Not used.
Segment
4
: Not used.
Segment
3
: Not used.
Segment
2
:
IGV
(Fast Speed Inspection).
This shows us the state of the Fast Speed Inspection contact.
Segment 2 is on when the contact is closed to request the Fast Speed Inspection.
Segment 2 is off in the reverse case.
Segment
1
:
TACQ2
(Anti-creep 2).
This shows the state of Anti-creep 2.
Segment 1 is on if the contact is closed when Anti-creep 2 has drawn back in.
Segment 1 is off in the reverse case.
Segment
0
:
TACQ1
(Anti-creep 1).
This shows us the state of Anti-creep 1.
Segment 0 is on if the contact is closed when Anti-creep 1 had drawn back in.