Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 85
INPUTS DEFINITIONS
• Ram Address
12
:
best displayed in segment mode.
Segment
7
: Not used.
Segment
6
: Not used.
Segment
5
: Not used.
Segment
4
:
MTH
(Oil Temperature Measure).
Segment 4 is on when the MTH 0V contact is open or when the temperature probe has
reached a certain value.
Segment 4 is off in the reverse case.
Segment
3
:
STH
(Thermic Probe).
This shows us the state of the thermostat (STH and 0V).
Segment 3 is off when the contact is closed in normal operating mode.
Segment 3 is on in the reverse case.
Segment
2
:
10
(Level 10 of the Safety Lane).
This shows us the state of the safety lanes at level 10 of the safety lane.
Segment 2 is on when the safety lane connection is closed up to level 10.
Segment 2 is off in the reverse case.
Segment
1
:
8
(Level 8 of the Safety Lane).
This shows us the state of the safety lanes at level 8 of the safety lane.
Segment 1 is on when the safety lane connection is closed up to level 8.
Segment 1 is off in the reverse case.
Segment
0
:
6
(Level 6 of the Safety Lane).
This shows us the state of the safety lanes at level 8 of the safety lane.
Segment 0 is on when the safety lane connection is closed up to level 6.
Segment 0 is off in the reverse case.