INPUTS DEFINITIONS
Ram Address
10
:
best displayed in segment mode.
Segment
7
: Not used.
Segment
6
: Not used.
Segment
5
: Not used.
Segment
4
:
FF2
(Rear Door Close Button).
This shows us the state of the Rear Door Close Button (FF2 et 0V).
Segment 4 is on when the contact is closed for a forced closure command..
Segment 4 is off in the reverse case.
Segment
3
:
COI2
(Rear Door Safety Knuckle Input).
This shows us the state of the Rear Door Safety Knuckle Input (CO12 and 0V).
Segment 3 is on when the contact is closed.
Segment 3 is off in the reverse case.
Segment
2
:
CS2
(Rear Door Photocell Input).
This shows us the state of the Rear Door Photocell Input (CS2 and 0V).
Segment 2 is off when the contact is closed, i.e., when the photocell is unbroken.
Segment 2 is on when the photocell detects something.
Segment
1
:
FCFE2
(Rear Door Close End Limit).
This shows us the state of the Rear Door Close End Limit (FCFE2).
Segment 1 is off when the Rear Door Close End Limit is closed, i.e., when the door is not
completely shut.
Segment 1 is on when the Rear Door Close End Limit is open, i.e., when the door is
completely closed.
Segment
0
:
FCOU2
(Rear Door Open End Limit).
This shows us the state of Rear Door Open End Limit (FCOU2).
Segment 0 is off when the Rear Door Open End Limit is closed, i.e., when the door is not
completely open.
Segment 0 is on when the Rear Door Open End Limit is open, i.e., when the door is