Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 82
INPUTS DEFINITIONS
• Ram Address
0F
:
best displayed in segment mode.
Segment
7
: Not used.
Segment
6
: Not used.
Segment
5
: Not used.
Segment
4
:
FF1
(Front Door Close Button).
This shows us the state of the Front Door Close Button.
Segment 4 is on when the contact is closed for a command to force the door closed.
Segment 4 is off in the reverse case.
Segment
3
:
COI1
(Front Door Safety Knuckle Input).
This shows us the Front Door Safety Knuckle Input (COI1 and 0V).
Segment 3 is on when the contact is closed.
Segment 3 is off in the reverse case.
Segment
2
:
CS1
(Front Door Photocell Input).
This shows us the state of the Front Door Photocell Input (CS1 and 0V).
Segment 2 is off when the contact is closed, i.e., when the photocell is unbroken.
Segment 2 is on when the photocell detects something.
Segment
1
:
FCFE1
(Front Door Close End Limit).
This shows us the Front Door Close End Limit (FCFE1 and 0V).
The segment 1 is off when the Front Door Close End Limit is closed, i.e., when Door 1 is
not completely closed.
The segment 1 is on when the Front Door Close End Limit is open, i.e., when Door 1 is
completely closed.
Segment
0
:
FCOU1
(Front Door Open End Limit).
This shows us the state of the Front Door Open End Limit (FCOU1 and 0V).
Segment 0 is off when the Front Door Open End Limit is closed, i.e., when the door 1 is
not completely opened.
Segment 0 is on when the Front Door Open End Limit is open, i.e., when Door 1 is
completely opened.