Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 80
INPUTS DEFINITIONS
Segment
4
:
DNH
(Oil Level Fault) HYDRAULIC.
This shows us the state of the contact detecting the minimum oil level rendering further
travel dangerous for the equipment.
Segment 4 is on when the contact is closed in the case of a fault.
Segment 4 is off in the reverse case.
Segment
3
:
RP
(Low Velocity Contactor Control) TRACTION.
This shows us the state of the low velocity contactor control (PV).
Segment 3 is on when the PV contactor is on.
Segment 3 is off in the reverse case.
Segment
3
:
NHM
(Minimum Oil Level) HYDRAULIC.
This shows us the state of the contact detecting the minimum oil level which is no longer
dangerous for the equipment, but which still needs a little oil.
Segment 3 is on when the contact is closed due to a lack of oil.
Segment 3 is off in the reverse case.
Segment
2
:
RG
(High Velocity Contactor Control) TRACTION.
This shows us the state of the high velocity contactor control (GV).
Segment 2 is on when the GV contactor is on.
Segment 2 is off in the reverse case.
Segment
2
:
RL
(Ligne Contactor Control) HYDRAULIC.
This shows us the state of the path contactor (L).
Segment 2 is on when the contactor is on.
Segment 2 is off in the reverse case.
Segment
1
:
RM
(Up Contactor Control) TRACTION.
This shows us the state of the up contactor (MO).
Segment 1 is on when contactor MO is on.
Segment 1 is put off in the reverse case.
Segment
1
:
RY
(Star Contactor Control) HYDRAULIC.
This shows us the state of the star contactor (Y).
Segment 1 is lit when contactor Y is on.
Segment 1 is off in the reverse case.
Segment
0
:
RD
(Down Contactor Control) TRACTION.
This shows us the state of the down contactor (DE).
Segment 0 is lit when contactor DE is on.
Segment 0 is off in the reverse case.
Segment
0
:
R
∆
(Delta Contactor Control) HYDRAULIC.
This shows us the state of the Delta contactor (∆).
Segment 0 is on when the ∆ contactor is on.
Segment 0 is off in the reverse case.