Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 78
INPUTS DEFINITIONS
• Ram Address
06
:
best displayed in segment mode.
Segments
1
to
7
:
D1 - 7
(Landing Calls for Down, 1 to 7).
They show us respectively the state of the contacts of the landing call for Down D1 to D7
with the common COMB button.
The corresponding segments are on when the contacts are closed to make a call.
The corresponding segments are off in the reverse case.
Segment
0
:
M0
(Landing Calls for Up, 0).
• Ram Address
09:
best displayed in segment mode.
Segments
0
to
7
:
NF0 - 7
(Levels Damaged by Fire, 0 to 7).
They show us respectively the state of the levels damaged by fire contacts NF7 to NF0
with 0V.
The corresponding segments are on when the contacts are closed to indicate levels
damaged by fire and thus not to serve them.
The corresponding segments are off in the reverse case.
• Ram Address
0A:
best displayed in segment mode.
Segments
0
to
7
:
NF8 - 15
(Levels Damaged by Fire, 8 to 15).
They show us respectively the state of the levels damaged by fire contacts NF7 to NF0
with 0V.
The corresponding segments are on when the contacts are closed to indicate the levels
damaged by fire and thus not to serve them.
The corresponding segments are off in the reverse case.
• Ram Address
0C
:
best displayed in segment mode.
Segment
7
:
SU
(Overload)
This shows us the state of the overload contact (SU and 0V).
Segment 7 is on when the contact is closed, i.e., in overload.
Segment 7 is off in the reverse case.
Segment
6
: Not used
Segment
5
:
ED
(Extreme Down Contact).
This shows us the state of the Extreme Down contact (ED and 0V).
Segment 5 is off when the contact is closed, i.e., when the car is not on ED.
Segment 5 is on when the car is on ED.