Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 75
PARAMETER DEFINITIONS
• Par Address
CO
: Temperature up to which the distance C8 is chosen, best displayed
in hexadecimal.
At this address, in the context of the SLOW SPEED DISTANCE VARIATION OF THE OIL
TEMPERATURE IN THE HYDRAULIC UNIT function, we program the temperature to
which we will use the slow speed distance programmed into address C8 (in %).
• Par Address
C1
: Temperature up to which the distance C9 is chosen, best displayed in
hexadecimal.
We program the temperature up to which we will use the slow speed distance
programmed into address C9 (in %).
• Par Address
C2
: Temperature up to which the distance CA is chosen, best displayed
in hexadecimal.
We program the temperature up to which we will use the slow speed distance
programmed into address CA (in %).
• Par Address
C3
: Temperature up to which the distance CB is chosen, best displayed
in hexadecimal.
We program the temperature up to which we will use the slow speed distance
programmed into address CB (in %).
• Par Address
C4
: Temperature up to which the distance CC is chosen, best displayed
in hexadecimal.
We program the temperature up to which we will use the slow speed distance
programmed into address CC (in %).
• Par Address
C5
: Temperature up to which the distance CD is chosen, best displayed
in hexadecimal.
We program the temperature up to which we will use the slow speed distance
programmed into address CD (in %).
• Par Address
C6
: Temperature up to which the distance CE is chosen, best displayed in
hexadecimal.
We program the temperature up to which we will use the slow speed distance
programmed into address CE (in %).
• Par Address
C7
: Temperature up to which the distance CF is chosen, best displayed in
hexadecimal.
We program the temperature up to which we will use the slow speed distance
programmed into address CF (in %).