Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 70
PARAMETER DEFINITIONS
Segment
3
:
OUAVAP2N0
(Open Before Stop of Door 2 at
Level 0).
We program segment 3 to " 1 " when we want to carry out an opening before stop of door
2 at level 0.
We program segment 3 to " 0 " in the reverse case.
Segment
2
:
STPOU0
(Parking Door 2 Open at Level 0).
We program segment 2 to " 1 " when we want to park the car with door 2 open at level 0.
We program segment 2 to " 0 " in the reverse case.
Segment
1
:
SER2IN0
(Service 2 Not Allowed at Level 0).
We program segment 1 to " 1 " when the opening of door 2 at level 0 is not allowed.
We program segment 1 to " 0 " when we allow the opening of door 2 at level 0.
Segment
0
:
OUNSIM0
(Non Simultaneous Opening at Level 0).
We program segment 0 to " 1 " when the simultaneous opening of doors 1 and 2 at level 0
is not allowed (locking effect).
We program segment 0 to " 0 " when we allow the simultaneous opening of doors 1 and 2
at level 0.
This function can only be used in the double service selective.
Par Address
69
: best displayed in segment mode.
At this address, we define the functioning of door 2 for level 1.
Par Address
6a
:
..... same for level 02.
Par Address
6b
:
..... same for level 03.
Par Address
6c
:
..... same for level 04.
Par Address
6d
:
..... same for level 05.
Par Address
6e
:
..... same for level 06.
Par Address
6f
:
..... same for level 07.
Par Address
70
:
..... same for level 08.
Par Address
71
:
..... same for level 09.
Par Address
72
:
..... same for level 10.
Par Address
73
:
..... same for level 11.
Par Address
74
:
..... same for level 12.
Par Address
75
:
..... same for level 13.
Par Address
76
:
..... same for level 14.
Par Address
77
:
..... same for level 15.