PARAMETER DEFINITIONS
Par Address
5F
:
TRAUN0
best displayed in segment mode.
Segment
7
: Not used.
Segment
6
: Not used.
Segment
5
: Not used.
Segment
4
:
STPREG
(thermostat Regulation).
We program segment 4 to " 1 " if we want to operate a thermostat for the SLOW SPEED
DISTANCE IN RELATION TO THE OIL TEMPERATURE IN THE HYDRAULIC UNIT
function.
See the parameters to addresses 5F, segment 1, C0 TO C7 AND C8 TO CF.
We program segment 4 to " 0 " in the reverse case.
Segment
3
:
DCTQET
(Doubling the Pawl Control Speed).
We program segment 3 to " 1 " when we want to double the time allowed for the pawl
control.
We program segment 3 to " 0 " in the reverse case.
Segment
2
: Not used.
Segment
1
:
REGDRAL
(Slow Speed Distance Regulation).
We program segment 1 to " 1 " if we want to operate the SLOW SPEED IN
RELATION TO THE OIL TEMPERATURE IN THE HYDRAULIC UNIT function.
See the parameters to addresses 5F, segment 4, C0 to C7 and C8 to CF.
We program segment 0 to " 1 " in the reverse case.
Segment
0
: Not used.
Par Address
60
: best displayed in segment mode.
At this address, we set out the desired mechanical characteristics of DOOR 2:
The relays which drive door 2 are those mounted outside the door.
Segment
7
: Not used.
Segment
6
:
VERSTF2
(Door Forced when Closed).
We program segment 6 to " 1 " when we want to provide a door close signal even if the
closed limit has been reached, but 8 has not yet been closed.
If a mechanical problem means that in spite of everything 8 from the safety chain is not
closed, the closure relay will drop when the door integrator time has elapsed.
We program 6 to " 0 " in the reverse case.