Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 60
PARAMETER DEFINITIONS
Segment
2
:
MSTPMP1
(Door 1 Forced Closure when Moving).
We program segment 2 to " 1 " when we want to give a door close signal while the car is
moving.
We program segment 2 to " 0 " in the reverse case.
Segment
1
:
AMPSEC1
(Door 1 Drift OK).
If we program this segment to " 1 " and door 1 does not have a close limit , the Series 32
will provide a close signal until 8 is closed. If the door drifts open and 8 is open, the door
close signal is NOT given again. Only if a call is made is the door close signal given.
With this type of door, we always program the option Forced Door Closure when Moving.
We program segment 1 to " 0 " when this option is not required.
Segment
0
:
MSTPRP1
(Permanent Door 1 Signal).
We program segment 0 to " 1 " to keep the door 1 open or close signal even if the open or
closed limit has been reached.
We program segment 0 to " 0 " in the reverse case.
• Par Address
41
:
TPO1
(Door 1 Timing) best displayed in hexadecimal.
At this address, we program the timing of door 1 in seconds and hex.
We can program a value of 1 to 255 seconds.
See page 94 for the conversion between decimal and hex, 0 to 255 ....... 00 to FF.
• Par Address
42
:
TREP1
(Door 1 Re-Open Time) best displayed in hexadecimal.
At this address we program the time the door stays open when a re-open signal has been
given (COI or CS).
This time is programmed in seconds and hex (from 1 to 255 seconds).
See page 94 for the conversion between decimal and hex, 0 to 255 ....... 00 to FF.
• Par Address
43
:
NIVMHS
(Floor Out of Service) best displayed in hexadecimal.
At this address, we program the floor where the car parks when we use the " out of service
" function.
If we wish the car to stay where it is the moment we activate the function, program " 0 " to
segments 6 and 7.
If we wish the car to park door(s) open or closed, we do this by switching on segment 7 for
door 1 and segment 6 for door 2.
Segment
2
at address
09
(
MHSPF
) will thus be switched off.