Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 55
PARAMETER DEFINITIONS
• Par Address
1F
:
TPRAU
(Homing Time) best displayed in hexadecimal.
At this address, we program the time it takes from the moment the apparatus is no longer
sought and its automatic return to a particular level.
This time is programmed in seconds and hex.
We can program a value from 1 to 255 seconds.
If we program 00, there is no homing.
See page 94 for the conversion between decimal and hex, from 00 to 255 ....... 00 to FF.
As concerns this timing, it is necessary to program the level to which the apparatus must
return to address 20.
• Par Address
20
:
NIVRAU
(Homing Level) best displayed in hexadecimal.
At this address, we program, in hex, the address to which a cabin will return, if it is not
sought after a certain delay which is contained in address 1F.
See page 94 for the conversion between decimal and hex, from 0 to 255 ....... 00 to FF.
Segment
5
:
TRAPM
(Lengthened Homing Time).
We program segment 5 to " 1 " if we want the base units of the door timings to extend from
1 to 2.5 seconds, thus allowing times from 5 seconds to 10 minutes.
We program segment 5 to " 0 " in the reverse case.
• Par Address
21
:
TGONG
(GONG Time) best displayed in hexadecimal.
At this address, we program the length of time during which the GONG (SPG1 to 3) exit is
activated.
This time is programmed at intervals of 0.1 seconds and in hex.
We can program a value from 0.1 to 10 seconds.
See page 94 for the conversion between decimal and hex, from 00 to 255 ....... 00 to FF.
• Par Address
22
:
COMDEM
(Trip Counter) best displayed in decimal.
The Series 32 has a 6 figure trip counter, and so can memorise 999999 movements.
Address 22 changes the 2 right-hand figures.
• Par Address
23
:
COMDEM
(Trip Counter) best displayed in decimal.
Address 23 increments the 2 middle figures.
• Par Address
24
:
COMDEM
(Trip Counter) best displayed in decimal.
Address 24 increments the 2 left-hand figures.