PARAMETER DEFINITIONS
Par Address
11
: best displayed in segment mode.
Segment
0
to
7
:
OPTOM
(Car Calls Masking 08 to 15).
Par Address
12
: Not used.
Par Address
13
: best displayed in segment mode.
Segment
0
to
7
:
(Mask the Landing Calls for Up, from levels 0 to 7).
We program the corresponding segments to " 1 " when we want the Series 32 to respond
to the corresponding landing calls for up.
We program the corresponding segments to " 0 " when we do not want the Series 32 to
respond to the corresponding landing calls for up.
Par Address
14
: best displayed in segment mode.
Segment
1
to
7
:
(Mask the Landing Calls for Up, from levels 8 to 15).
Par Address
15
: Not used.
Par Address
16
: best displayed in segment mode.
Segment
1
to
7
:
(Mask the Landing Calls for Down, from levels 1 to 7).
We program the corresponding segments to " 1 " when we want the Series 32 to
respond to the corresponding landing calls for down.
We program the corresponding segments to " 0 " when we do not want the Series 32 to
respond to the corresponding landing calls for down.