Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 51
PARAMETER DEFINITIONS
• Par Address
0D
:
TINS
(Inspection Time).
Best displayed in hexadecimal mode.
At the address 0D, we program the maximum time, in seconds and hex, allowed to run on
inspection.
We can program a value from 01 to 255 seconds.
If we stop and then start again, we use this maximum time length again.
If the Series 32 interrupts the movement because we have exceeded the allowed time, it is
necessary to wait this length of time before re-starting the inspection.
The same applies for homing control mode.
If the service timing is programmed to 00 then the inspection travelling limitation does not
exist.
See page 94 for conversion between hex and decimal, from 00 to 255 ....... 00 to FF.
• Par Address
0E
:
TCAPGV
(Tape Head Beam Broken Time in Fast Speed).
Best displayed in hexadecimal mode.
At this address, we program the maximum allowed during which a tape head beam can be
interrupted in fast speed.
We can program a value from 02 to 25.5 seconds at intervals of 0.1 seconds.
If we program a value under 2 seconds (20 tenths of seconds), a 2 second value will be
imposed.
See page 94 for the conversion of hex to decimal from 00 to 255 ....... 00 to FF.
• Par Address
0F
:
TCAPPV
(Tape Head Beam Broken Time in Slow Speed).
Best displayed in hexadecimal mode.
At address 0F, we program the maximum allowed time during which a tape head beam
can be interrupted in Slow Speed.
We can program a value from 3 to 25.5 seconds at intervals of 0.1 seconds.
If we program a value under 3 seconds (30 tenths of seconds) , a 3 second value will be
imposed.
See page 94 for the conversion between decimal and hex, from 00 to 255 ....... 00 to FF.
• Par Address
10
: best displayed in segment mode.
Segment
0
to
7
:
OPTOM
(Car Calls Masking 0 to 7).
We program the corresponding segments to " 1 " when we want the Series 32 to reply to
the corresponding landing calls.
We program the corresponding segments to " 0 " when we do not want the Series 32 to
reply to the corresponding landing calls.