Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 49
PARAMETER DEFINITIONS
Segment
2
:
MASMPX
(Multiplex Mass).
Programming segment 2 to " 1 " results in the Series 32 SLAVE not taking any notice of a
Mass Fault.
Programming segment 2 to " 0 " results in the reverse.
Segment
1
:
IPF
(Re-Levelling with Door Closed).
Programming segment 1 to " 1 "results in re-levelling with closed doors.
This function is programmed in relation to address parameter 02 or 63, segment 5.
Programming segment 1 to " 0 " results in the reverse.
Segment
0
:
IPO
(Re-Levelling with Door Open).
Programming segment 0 to " 1 " results in re-levelling with the door open and can thus
control a bridging device from the safety chain.
This function is programmed in relation to the address parameter 02 or 63, segment 5.
Programming segment 0 to " 0 " results in the reverse.
Par Address
09
: best displayed in segment mode.
Segment
7
:
GONGAR
(GONG on stopping).
Programming segment 7 to " 1 " results in the GONG exit operating when the apparatus is
immobilised.
Programming segment 7 to " 0 " results in the GONG exit operating in the Slow Speed
Distance passage.
Segment
6
:
IGPPRO
(Temporary Door Integrator).
Programming segment 6 to " 1 " renders the door integrator fault temporary.
Programming segment 6 to " 0 " results in the reverse.
Segment
5
:
IGV
(High Speed Inspection).
Programming segment 5 to " 1 " results in high speed inspection.
Programming segment 5 to " 0 " results in the reverse.
Segment
4
:
PFLSGV
(No Fast Speed Direction Indicator).
Programming segment 4 to " 1 " results in the direction arrows being turned off at
high speed.
Programming segment 4 to " 0 " results in the reverse.