Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 45
PARAMETER DEFINITIONS
Segment
4
:
RMLIFT
(Control System MLIFT).
We program segment 4 to " 1 " if the Series 32 is to drive a variable frequency speed
control system.
We program segment 4 to " 0 " in the reverse case.
Segment
3
:
NIVSIN
(Levels damaged by fire).
We program segment 3 to " 1 " if the Series 32 is to manage levels damaged by fire.
We program segment 3 to " 0 " in the reverse case.
Segment
2
:
DSERVS
(Double Selective SERVice).
We program segment 2 to " 1 " if the Series 32 is to manage 2 service selective.
Segment
1
:
OUAVAR
(Open Before Stop).
We program Segment 1 to " 1 " if the Series 32 is to carry out the OPEN BEFORE STOP
function and therefore to control a bridging device from the safety chain.
We program Segment 1 to " 0 " in the reverse case.
Segment
0
: Not used.
• Par Address
03
:
NBOPER
(Number of Door Operators).
Best displayed in hexadecimal mode.
At this address, we program the number of door operators to be operated.
As the Series 32 can only control 2 automatic doors, only the values 00, 01 or 02 can be
programmed.
• Par Address
04
:
NIVSUP
(Upper Level).
Best displayed in hexadecimal mode.
At this address, we program the UPPER LEVEL of the installation (total number of levels
minus 1, thus 1 to 15).
Here are the conversions between the decimal and hexadecimal numbers 00 to 15 ...... 00
to 0F.
00 decimal = 00 hex 08 decimal = 08 hex
01 decimal = 01 hex 09 decimal = 09 hex
02 decimal = 02 hex 10 decimal = 0A hex
03 decimal = 03 hex 11 decimal = 0B hex
04 decimal = 04 hex 12 decimal = 0C hex
05 decimal = 05 hex 13 decimal = 0D hex
06 decimal = 06 hex 14 decimal = 0E hex
07 decimal = 07 hex 15 decimal = 0F hex