Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 38
LIST OF VECTOR FAULT CODES
FAULTS DISPLAYED BY THE VECTOR DRIVE (VEC01 Board)
The B32 fault code stack is found at Address 28, 29, 2A, 2B, 2B, 2C, 2D, 2E,
2F, 30 and 31. At Address 28 the most recent fault and at Address 31 the oldest
recorded fault.
BEFORE LEAVING THE SITE, SET THE FAULT LIST BACK TO 00.
IN THIS WAY YOU CAN KEEP BETTER TRACK OF ANY BREAKDOWNS.
WARNING :
PLEASE TAKE PRECAUTIONS WHEN YOU SEND US YOUR ELECTRONIC BOARDS
(USE ANTI-STATIC BAGS)
FAULT
DESIGNATION VISUALISATION
-00-
FUNCTIONING CORRECTLY. No fault
-10-
INVERSION IN THE ROTATION DIRECTION (DETECTED BY THE
TAPE HEAD)
Phase inversion
-11-
CONSEQUENCE OF A AND B SIGNALS CHANGING STATE AT
THE SAME TIME
Tape head
fault
-22-
SLIP INTEGRATOR. Integrator
-52-
« 10 » CUT WHILE IN MOTION. 10 cut while
in motion
-62-
FAULT WITH THE O03 TAPE HEAD. Tape head
counting irrational
-77- “S” CONTACTOR NOT DROPPED.
Contactor not realising
-78- “S” CONTACTOR NOT ENERGISED
Not programmed
-80-
POWER SUPPLY CAPACITOR (tc) MISSING AT START-UP. Current < 450 v at start-up
-81-
AVERAGE CURRENT HIGHER THAN ALLOWED CURRENT. Thermistor
-82-
REAL SPEED 15% HIGHER THAN PROGRAMMED NOMINAL
SPEED Vn.
Speed > 115% of the nominal
speed
-83-
INSPECTION SPEED EXCEEDS 0,6 M/S. Inspection speed > 0.6 m/s
-84-
RELEVELLING SPEED EXCEEDS 0,3 M/S. Relevelling speed > 0.3 m/s
-85-
REGENERATIVE POWER EXCEEDS 650V (BRAKE CIRCUIT
FAULT)
Regeneration
-86-
MISSING POWER SUPPLY DURING MOVEMENT COMMAND
(FUSE BLOWN OR CONTACTOR NOT ENERGISED.
No power while in motion
-87-
“LINE” CONTACTOR NOT DROPPED. Contactor not realising
-88-
SIMULTANEOUS « UP » AND « DOWN » COMMAND. Simultaneous
up and down
-89-
RADIATOR TEMPERATURE EXCEEDS 40 °. Radiator T°
-90-
AC CURRENT EXCEEDS MAX TRANSISTOR CURRENT. Power supply too high
-91-
TRANSISTOR N°1 FAULT. (TOP) Transistor N°1 (Top)
-92-
TRANSISTOR N°2 FAULT. Transistor N°2
-93-
TRANSISTOR N°3 FAULT. Transistor N°3
-94-
TRANSISTOR N°4 FAULT. Transistor N°4
-95-
TRANSISTOR N°5 FAULT. Transistor N°5
-96-
TRANSISTOR N°6 FAULT. (BOTTOM) Transistor N°6 (Bottom)
-97-
REGENERATIVE TRANSISTOR FAULT. Regenerative Transistor fault
-98-
PARAMETER FAULT Parameter fault
-99-
EEROM WRITING FAULT. Eerom writing fault
-100-
MOTOR INTENSITY > MAXI INTENSITY. Motor intensity > Max
-101-
INCREMENTAL ENCODER FAULT. Encoder fault
-102-
INCREMENTAL ENCODER SPEED +/- 15% FAULT. Encoder speed +/- 15% Advised
-103-
DIRECT APPROACH FAULT. MLIFT stop on
V0 movement
-104-
CURRENT MEASURING DEVICE NOT CONNECTED Not programmed
-AUTRE-