Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 35
LIST OF VECTOR PARAMETERS AND FINAL VALUES
* Opt parameter Detail - OPTion - Address 00E :
page 26.
Address Name Designation
Min
values
Max
values
Factory values
Finals
Values
Page
000
V0 Set-up speed 0,001 0,199 1/10 de V2 23
001
Iso Re-levelling speed 0,000
<
V0
0,020 m/s 23
002
Ins Inspection speed 0,20 0,60 0,50 m/s 23
003
V1 Intermediary speed 0,61
<
V2
0,61 m/s 23
004
V2 Full speed > V1 03,00
Clients specification
(m/s) 24
006
VSy Synchronous speed 0,000 9,999
Clients specification
(m/s) 24
008
DV2 V2 Slow down distance 0,000 9,999
Clients specification
(m) 24
00A
Acce Acceleration 02,0 25,5 3,0 s 25
00B
FrArr Brake stopping time 0,30 0,80 0,5 s 25
00C
FrDem Brake starting time 0,00 0,60 0,5 s 25
00D
Thermi Motor thermistor (A)
Clients specification
(A) 25
00E
Opt Hardware option
Clients specification
(m/s) 26
00F
RgT° Temperature Sonde Calibration 0 10 4 °C
010
Model Vector model 2 9
Clients specification
27
011
Tmor Transistor pause time 1,5 µs
012
IFlux Flux current max 000,1 999,9 Number of horse power (A) 27
014
IFmin Flux current min 000,1 999,9 IFlux / 2 = (A) 27
016
Gliss Motor slip 02,0 20,0
1500 RPM
1500
100
×
= %
28
017
ETFDM0 Up starting brake time difference 0,00 2,55 0,00 s
018
Jreg Inertia 005 %
019
GP max Max Proportional Gain > 12 Hz 015
01A
GP min Min Proportional Gain < 12 Hz 004
01B
GI max Max integral Gain 010
01C
GI min Min integral Gain 001
01D
AFLuD Additional starting Flux 00,0 A
01E
GI Dep Start up integral Gain 005
01F
GP Dep Start up Proportional Gain 005
020
T Dema Start up Voltage 006 %
021
G Stabi Stabilisation Gain 015
022
FTmax Max Voltage Frequency 050 Hz
023
FMinD Min Starting Frequency 0,10 Hz
024
NCode N° Encoder Teeth 0500 2500 500 (500 < x < 2500) 28
026
NPole N° of motor Poles 004 006 4 or 6 poles
(if 6 poles, NCode=750mini)
28
027
Country Country Language
F DGB SP
,,,
29
Address Name Seg 7 Seg 6 Seg 5 Seg 4 Seg 3 Seg 2 Seg 1 Seg 0
00E
Opt ML220V D65° APPDIR RETSEC MLI BATERI NOBAND IG
FACTORY VALUE
00000 or 1 010
FINAL VALUE