Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 34
EXPLANATION OF VARIABLES (2/2)
Address
114
:
Vt
, Lift speed in metres per second (m/s)
At this address can be read the car speed.
Address
116
:
Codeur
, Incremental encoder no Unit
At this address can be read the counting of the incremental encoder mounted on the
motor.
Address
118
:
Recup
, Energy regeneration in percent (%)
At this address can be read the percentage of energy consumed in the x
regenerative resistors. (x = number of regenerative resistors depending of the drive model)
Address
11A
:
Tmot
, motor power supply current in percent (%)
At this address can be read the power current applied to the motor.
Address
120
:
GD
, Deceleration Gradient in V2 speed in metre per second squared (m/s²)
At this address can be read the deceleration slope associated with the different
speed.
Address
122
:
DRal
, Slow-down distance in metre (m)
At this address can be read the slow-down distance still to run.
Address
12A
:
I Cap1
, Current measuring device 1 no Unit
At this address can be read the information given by the current measuring device 1
Note : At Stop the information should be between 500 and 524.
Address
12C
:
I Cap2
, Current measuring device 2 no Unit
At this address can be read the information given by the current measuring device 2.
Note : At Stop the information should be between 500 and 524.
Address
12E
:
I Cap3
, Current measuring device 3 no Unit
At this address can be read the information given by the current measuring device 3.
Note : At Stop the information should be between 500 and 524.