EXPLANATION OF VARIABLES (1/2)
• Address
103
:
T°
, Radiator Temperature in degrees Celsius (°)
At this address can be read the power transistors cooling radiator temperature.
• Address
104
:
TCont
, Capacitor Current in Volts (V)
At this address can be read the D.C. net capacitor terminal current.
• Address
108
:
Imot
, Motor Current in Amps (A)
At this address can be read the current in each phase of the motor.
• Address
10A
:
DV0
, V0 stopping distance in metres (m)
At this address can be read the distance necessary to smooth V0 into zero speed.
• Address
10B
:
Diso
, Relevelling stopping distance in metres (m)
At this address can be read the distance necessary to smooth VISO into zero
speed.
• Address
10C
:
DIns
, Inspection slow-down distance i
n metres (m)
At this address can be read the slow-down distance associated with the inspection
speed VINS.
• Address
10E
:
DV1
, V1 slow-down distance in metres (m)
At this address can be read the slow-down distance associated with the
intermediate speed V1.
• Address
110
:
Fre
, Frequency sent to the motor in Hertz (Hz)
At this address can be read the instantaneous frequency applied to the motor.
• Address
112
:
Con
, reference in Hertz (Hz)
At this address can be read the reference/Ideal frequency to be followed.