Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 30
EXPLANATION OF INPUTS (1/2)
Address
100
:
En1
, Inputs 0 to 7.
Segment
7
: NOT USED.
100 En1
10000000
Segment
6
:
V2
, Speed V2. (Full speed)
100 En1
01000000
Indicates the State of the input for speed V2.
Segment 6 lights up when the lift is required to move at speed V2.
Segment 6 is not lit otherwise.
Segment
5
:
V1
, Speed V1. (Intermediate speed)
100 En1
00100000
Indicates the State of the input for speed V1.
Segment 5 lights up when the lift is required to move at speed V1.
Segment 5 is not lit otherwise.
Segment
4
:
V0
, Speed V0.
100 En1
00010000
Indicates the State of the input for speed V0.
Segment 4 lights up when the lift is required to move at speed V0.
Segment 4 is not lit otherwise.
Segment
3
:
INS
, Inspection speed.
100 En1
00001000
Indicates the State of the inspection input.
Segment 3 lights up when the lift is required to move on inspection.
Segment 3 is not lit otherwise.
Segment
2
:
VISO
, Relevelling speed.
100 En1
00000100
Indicates the State of the relevelling input. (VISO+ & VISO-)
Segment 2 lights up when the lift is required to relevel.
Segment 2 is not lit otherwise.
Segment
1
:
DE
, Down.
100 En1
00000010
Indicates the State of the Down input.
Segment 1 lights up when the lift is required to go down.
Segment 1 is not lit otherwise.