Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 29
EXPLANATION OF PARAMETERS (7/7).
Address
027
:
Country
, Language.
At this address can be programmed the language to be used on the VEC03 programming
tool.
* In Germany, the Inspection speed can go up to 0,80 m/s and the levelling speed up to
0,50 m/s.
Address
034
:
Dem
, Number of starts. . => 0 0 0 0 x x x x
At this address, can be read the number of starts carried out by the lift and the 4 strong
weight bits can be modified.
Address
036
:
Dem
, Number of starts. => x x x x 0 0 0 0
At this address, can be read the number of starts carried out by the lift and the 4 light
weight bits can be modified.
Address
041
:
Test
, Transistor test.
At this address, can be written 55 to check the transistors.
All of the LEDs turn red if all of the transistors are working properly.
Address
042
:
Prog
, Type of Programme.
At this address, the selected programme can be read.
VEC (VECtoriel) Vector, SCA (SCAlaire), ARB (ARBre lent) Gear Less.
Address
043
:
TMan
, Type of Controller.
At this address, the type of controller associated with the B32 can be read.
Normal (AUTINOR Controller or with a VEC06 interface board),
1Vit (1 speed controller), 2Vit (2 speed controller)
Address
044
:
Mcode
, Memorisation of a personal code number.
At this address can be memorised a personal code number to program against all chance
intervention. The equipment set with the factory code 0000 allowing complete and
permanent access to the set of settings.
After programming your code (Don’t forget to take note of it), the address 044 disappears.
If you want to modify the settings, enter your Code at the address 046.
Address
046
:
Code
, Access Code.
At this address, enter your Code to unlock the address 044 in order to modify the setting
and/or change the memorised code.
Possible choice : France, English, Deutsch *, Español