Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 27
EXPLANATION OF PARAMETERS (5/7).
Segment
0
:
IG
, Integrator.
00E Opt
00000001
Segment 0 is programmed ON when the B32 slip integrator is to be activated.
Segment 0 is programmed OFF if this is not desired .
Address
010
:
Modele
, B32 Model.
At this address is programmed the B32 model number. See the sticker on the Plexiglas or
on the current measuring device label (VEC02M).
Address
012
:
IFlux
, Maximum flux current.
At this address is programmed the maximum flux current. Normally, this current is
measured with no load at 1500 tr/mn. This measurement is rarely possible on site, so the
« empirical » method is to program the number of horsepower as found on the motor
plaque.
Example :
If the motor plaque says 12 HP Program 12,0
If the motor plaque says 12 kW, transform into HP, 12 / 0,736 = 16,3 program 16,3
Address
014
:
IFmin
, minimum flux current.
At this address is programmed the minimum flux current, which is approximately one half
of the maximum flux current (see address 012). This parameter decreases the motor
vibrations at low frequency.
Unit :
None
Mini :
2
Maxi :
9
Factory value :
Clients specification
Unit :
Ampere (a)
Mini :
000,1 A
Maxi :
999,9 a
Factory value :
Clients specification
Unit :
Ampere (a)
Mini :
000,1 A
Maxi :
999,9 a
Factory value :
IFlux / 2 = (A)