Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 25
EXPLANATION OF PARAMETERS (3/7).
• Address
00A
:
Acce
, Acceleration.
At this address is programmed the time to reach V2 speed.
• Address
00B
:
FrArr
, Brake time on stopping.
At this address is programmed the time to stabilise the rotor before the brake is dropped.
• Address
00C
:
FrDem
, Brake time on start-up.
At this address is programmed the time during which the rotor is stabilised to allow the
brake to lift correctly before start-up.
• Address
00D
:
Thermi
, Motor thermistor.
At this address is programmed the current at which the electronic thermical relay is
activated. (since programme V02)
The thermal relay switches switch off if the motor intensity (Imot) is higher than the thermal
intensity (Ith) for longer than 3,5 seconds or if the motor intensity (Imot) is 1,5 A higher
than the termal intensity (Ith).
Imot can be seen at the address 108, page 33.
Unit :
second (s)
Mini :
02,0 s
Maxi :
25,5 s
Factory value :
03,0 s
Unit :
second (s)
Mini :
0,30 s
Maxi :
0,80 s
Factory value :
0,5 s
Unit :
second (s)
Mini :
0,00 s
Maxi :
0,60 s
Factory value :
0,5 s
Unit :
Ampere (A)
Mini :
....... A
Maxi :
....... A
Factory value :
Clients specification