Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 24
EXPLANATION OF PARAMETERS (2/7).
Address
004
:
V2
, Full speed V2.
At this address is programmed the Full speed.
Address
006
:
VSy
, Synchronous speed.
At this address is programmed the movement speed of the car when the motor turns at its
synchronous speed.
1500 t/min for a 4 pole motor 1000 t/min for a 6 pole motor
Formula :
Calculation of the synchronous speed for a 1500 t/min motor :
VSy
Reductor ration x roping
=
×
1500
60
π
d
π
= 3,14 - d = diameter of the pulley - Roping = 1 or 2 or 4
Address
008
:
DV2
, Slow-down distance on V2.
At this address is programmed the slow-down distance necessary when in full speed V2.
Unit :
metres per second (m/s)
Mini :
> V1
Maxi :
04,00 m/s
Factory value :
Clients specification
Unit :
metres per second (m/s)
Mini :
0,000 m/s
Maxi :
9,999 m/s
Factory value :
Clients specification
Unit :
metre (m)
Mini :
0,000 m
Maxi :
9,999 m
Factory value :
Clients specification
6
4
3
1.6
0.7
6
9
1
2
2.7
4.2
0.5
0
1
2
3
4
5
6
7
8
9
00.511.522.53
VITESSES EN METRE PAR SECONDE
DISTANCES EN METRE
D maxi
D mini
Figure 3
Slow-down distance
value (DV2) in fact of
the full speed (V2)