Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 23
EXPLANATION OF PARAMETERS (1/7).
• Address
000
:
V0
, V0.
At this address is programmed V0 which can also be used as a relevelling speed.
• Address
001
:
ISO
, Relevelling speed.
At this address is programmed the relevelling speed.
• Address
002
:
INS
, Inspection speed.
At this address is programmed the Inspection speed which can also be used as an
intermediate speed if V1 is not used.
This speed is taken into account when the inspection input (INS/ on K30) is activated
(VINS Led lit).
• Address
003
:
V1
, Intermediate speed V1.
At this address is programmed the Intermediate speed V1.
Units :
metres per second (m/s)
Mini :
0,001 m/s
Maxi :
0,199 m/s
Factory value :
1/10 of V2
Unit :
metres per second (m/s)
Mini :
0,000 m/s
Maxi :
< V0
Factory value :
0,020 m/s
Unit :
metres per second (m/s)
Mini :
0,20 m/s
Maxi :
0,60 m/s
Factory value :
0,50 m/s
Unit :
metres per second (m/s)
Mini :
0,61 m/s
Maxi :
< V2
Factory value :
0,61 m/s