Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 7
WHAT TO KNOW BEFORE STARTING OFF AT FULL SPEED (2/3)
2) To programme the Thermal Protection.
Read the nominal current written on the motor faceplate and copy the value
at address 00D of the drive.
3) Address 00E details (Hardware Option)
Segment 0: Intégrator.
Segment 3: MLi.
Segment 5: Direct approach.
Segment 6: 65°Défault temperature.
Segment 7: Mlift 220V.