Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 4
PROCEDURE TO BE FOLLOWED TO CARRY OUT THE
AUTOMATIC SET-UP OF LEVELS (3/4)
8) Release the « STOP » button on the car roof and go up to level 1 on inspection,
stopping exactly at floor level!
9) Press the « STOP » button on the car roof.
10) Press GM and GD at the same time for 5 seconds.
The software will memorise the height corresponding to level 1.
11) Repeat steps 7) to 9) until you reach the highest level.
12) Come back down to the lowest level.
By passing the ED magnets coming down, you automatically load the slow-down
distance used by all levels going up or coming down. In addition the value 80
programmed at address E0 will reset to 00 to exit the automatic level set-up
procedure.
13) Move the lift towards the machine room on inspection, and leave the car roof, leaving
the switch still on inspection.
14) Turn the MB32 VECTOR power off and then back on again.
If fault code 61 is shown on the communication tool, a mistake has been made
during the level set-up procedure, and the whole procedure needs to be done again
...
15) If the fault code 61 does not appear, cut the safety lane.
Copy down each floor height at addresses 80 to 9F in the table on page 5, so that later
on you can check the lift's stopping precision (table 1) and the slow down distance
read at addresses d0 and d1 (table 2).
16) Turn the inspection switch on the car roof to Normal.
17) Return to the machine room.
18) Read the chapter « What to know before starting of at full speed » before
reconnecting the safety lane. In this way you can check that the lift carries out
correctly its reset sequence.