Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 2
PROCEDURE TO BE FOLLOWED TO CARRY OUT THE
AUTOMATIC SET-UP OF LEVELS (1/4)
BEFORE STARTING:
This levelling adjustment is done in INSPECTION (INS) mode
and not in MAN. For this connect the inspection wire coming from
the car roof to INS, and bridge MAN and 0V.
Do not put the magnets on the tape, but take them with you, as well as this
installation manual.
This automatic relevelling procedure allows you to measure and register
directly in the controller the landing heights of each corresponding floor. Each level
corresponds to an altitude on the slotted tape.
The lowest level is 00 00.
PROCEDURE TO FOLLOW :
1) Turn the switch to INS.
2) Switch the MB32 VECTOR power off and then on again.
3) With the left-hand switch of the BG17 communication tool on PAR, programme
80 at address E0.
4) Climb onto the car roof and take the lift down to the lowest level. Stop exactly at
the floor level!
5) Press the « STOP » button on the car roof.
6) Press GM and GD at the same time for 5 seconds.
You can always correct the last registered height, as long as you have not moved
by more than 20 centimetres.
7) Position the ED magnet above the O03 tape-head at a height (D) corresponding
to the slow down distance required (see graph on next page).
Example: If the lift speed is 1.60 m/s, the graph page 3 recommends a slow down
distance (D) between 2 m 00 and 3 m 00, in our example: 2.50 m.
Vn :
D :
Nominal speed in metres per second.
Slow down distance in metres