INSPECTION LIMIT SWITCH
FAST SPEED INSPECTION
In France, to fulfil decree n° 95-826 of 30 June 1995, it is advised to install a limit switch for inspection.
Distances to fulfil when this device goes on are illustrated below.
TOP OF THE SHAFT
Decree 95-826: 1,50 m min
Standard NF P 82-211: 1 m + 0,035 v²
Decree 95-826: 1,80 m min
Standard NF P 82-211: no specified
MATERIAL IN SHAFT
Decree 95-826 : 0,80 m max
Standard: no specified
Sling (*)
CAR
> 0,25 m
Surface considered
Standard EN 81 § 8.13.1 b)
ACCESSIBLE SURFACE
> 0,12 m²AND
accessible
(*) The cross head are not considered as work surface because they must not be used during the movement of
the car (interpretation CEN n° 139)
IGV
Fast speed
inspection
Add.
09
Seg.
5
ADR/DON
MODIF
ECRIT
BG17
PAR
RAM
IN PROGRAMMING « IGV », THE CAR START
INSTANTLY IN FAST SPEED (GV) WHEN PUSHING
ON THE PUSH BUTTONS « GM » OR « GD »